RangeEasyLogic
Product nameEasyLogic PM11XXH RS
Device short namePM1130H
Product or component typeDual source energy meter
Complementary
Power quality analysisTotal harmonic distortion
Device applicationEnergy monitoring
Main or redundant power monitoring
Type of measurementCurrent
Voltage
Frequency
Power factor
Phase angle
RPM
Peak demand power
Harmonic distorsion (I THD & U THD)
Active power
Active energy
Metering typeUnbalance current
Power factor and displacement PF (signed, four quadrant)
Reactive power Q, Q1, Q2, Q3
Average current Iavg
Active, reactive, apparent energy (signed, two quadrant)
Active power P, P1, P2, P3
Frequency
Calculated neutral current
Voltage U21, U32, U13, V1, V2, V3
Unbalance voltage
Rotation speed
Demand power P, Q, S
Phase currents
Apparent power S, S1, S2, S3
Phase current I1, I2, I3 RMS
Average voltage Vavg
Counter functionsON-load source 1 hour counting
ON hour counting
ON-load source 2 hour counting
Power interruption
[Us] rated supply voltage48...277 V AC 45...65 Hz
48...277 V DC
Network frequency60 Hz
50 Hz
[In] rated current5 A
1 A
type of network2P
2P + N
3P
1P + N
3P + N
Maximum power consumption in VA4 VA at 240 V between phase and neutral
Maximum power consumption in W2 W at 240 V
Display type7 segments LED
Display colourRed
messages display capacity3 fields of 4 characters
Display digits12 digit(s) - 14.2 mm in height
Communication of dataLast cleared log
Reading of measurements
All counters
Revolution speed
Instantaneous and demand values
Tamperproof of settingsProtected by access code
Sampling rate32 samples/cycle
Measurement current5…6000 mA
SignalVoltage (impedance 5 MOhm)4 x
Current 0.005...10 A (impedance 0.3 MOhm)6 x
Measurement voltage35…480 V AC 50...60 Hz between phases
35…277 V AC 50...60 Hz between phase and neutral
277…999000 V AC 50...60 Hz with external VT
Frequency measurement range45…65 Hz
Measurement accuracyCurrent +/- 0.5 %
Voltage +/- 0.5 %
Frequency +/- 0.05 %
Power factor +/- 0.01
Reactive power +/- 2 %
Reactive energy +/- 2 %
Active power +/- 0.5 %
Apparent power +/- 0.5 %
Active energy +/- 0.5 %
Apparent energy +/- 0.5 %
Harmonic distorsion (I THD & U THD) +/- 5 %
Accuracy classClass 2 reactive energy conforming to IEC 62053-23
Class 0.5 active energy conforming to IEC 62053-22
Number of outputs1 relay
Output voltage300 V AC@2 A
Demand intervals1 s
Local signallingGreen LED: activity
Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Red LED: alternate source
Communication port protocolModbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Communication port supportRS485
Data recordingEnergy consumption logs
MaterialPolycarbonate
Flame retardanceV-0 conforming to UL 94
Mounting modeFlush-mounted
Mounting supportFramework
Provided equipmentInstallation guide
Installation categoryIII
Type of installationIndoor installation
Measurement categoryCategory III 480 V
Electrical insulation classClass II
Connections - terminalsCurrent circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s)
Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s)
Secondary circuit: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s)
Relay output: screw clamp terminals (rear) 0.33…3.31 mm² cable(s)
Tightening torqueCurrent circuit: 0.9…1 N.m Philips No 2 screwdriver
Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver
Control circuit: 0.9…1 N.m Philips No 2 screwdriver
Communication: 0.5…0.6 N.m Philips no 1 screwdriver
Secondary circuit: 0.5…0.6 N.m Philips no 1 screwdriver
Relay output: 0.5…0.6 N.m Philips no 1 screwdriver
Wire stripping lengthCurrent circuit: 3.68 mm
Voltage circuit: 7 mm
Control circuit: 7 mm
Communication: 7 mm
7 mm
StandardsIEC 61010-1:ed. 3
UL 61010-1:ed. 3
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
C-Tick
Width96 mm
Depth13 mm outside:
52 mm panel:
Height96 mm
Net weight300 g
Environment
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Emission tests conforming to FCC part 15 Subpart C
Emission tests conforming to FCC part 15 Subpart E
Overvoltage categoryIII
IP degree of protectionIP51 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-20…70 °C
Operating altitude<= 2000 m
Service life7 year(s)

Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.04 cm
Package 1 Width9.6 cm
Package 1 Length9.6 cm
Package 1 Weight285 g
Unit Type of Package 2S03
Number of Units in Package 218
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight5130 g
Unit Type of Package 3P06
Number of Units in Package 3144
Package 3 Height105 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight41.1 kg
There have been no reviews for this product yet.
Signup For Newsletter
we'll never share your email address with a third-party